If you wait long enough, everything comes back in style! Gold fixtures are the latest trend in luxury bathrooms and kitchens, but with a modern twist. No longer are we stuck with the boring, old polished brass! Champagne bronze and Brushed Gold fixtures are ushering in a new "Golden Age" in home decor.
How do you clean a brushed gold faucet?
Gold Basin Taps, Gold Tap Bathroom, Brushed Gold Basin Taps, Rose Gold Basin Tap, Gold Basin Mixer Taps Kaiping Jianfa Sanitary Ware Co.,Ltd. , https://www.jfsanitary.com
Submission:
**Proper Use and Installation of Integrated Orifice Flowmeters**
An integrated orifice flowmeter is primarily designed for sensing, transmitting, and calculating flow rates. It is commonly used in industrial applications to measure the flow of saturated steam, superheated steam, compressed air, non-flammable and non-explosive gases, and hot water. These devices are ideal for flow measurement, display, and on-line automatic control in various production processes.
One of the most critical precautions when commissioning the device is ensuring that the pressure lines are fully filled with water or that high-temperature steam has been cooled before operation. This prevents damage to the internal components and ensures accurate readings.
The straight pipe sections before and after the orifice plate must be smooth and free of obstructions. If the pipe surface is rough, the flow coefficient should be adjusted accordingly using a roughness correction factor. A sufficient length of straight pipe is required upstream of the orifice plate. If the upstream area is an open space or a large container with a diameter of at least 2D, the distance between the container and the orifice plate should not be less than 30D (or 15D). If there are other local resistance elements between the orifice and the open space, the minimum straight pipe length between the orifice and these elements should be at least 1D. The total length of the straight pipe between the flow elements should not be less than 30D (or 15D).
**How to Use the Integrated Orifice Flowmeter Correctly:**
1. **Filling the Pressure Guide Tubes:** The pressure guide tubes should be filled with cold water as the guiding medium. When measuring high-temperature steam, it's common to use cold water for initial filling. If the pipeline is not carrying steam, open the valve, pressure valve, and balance valve, close the drain valve, and inject cold water directly from the condensate tank until the system is fully filled. Alternatively, you can close the balance and pressure valves, open the primary valve, and introduce high-temperature steam slowly to cool it down into water. However, this method is rarely used due to the risk of damaging the meter from excessive heat.
It’s crucial to note that if the pressure guide tube is not filled with water or if the temperature is too high, the device must not be put into operation. For compressed air and cold water measurements, the medium itself is used directly.
2. **Exhausting the Differential Pressure Transmitter:** After filling the pressure guide tubes with water, some gas may accumulate in the differential pressure transmitter’s pressure chambers, which can affect the accuracy of the readings. To prevent this, loosen the bolts on the bottom of the positive and negative pressure chambers. In most cases, a newly commissioned instrument doesn’t require draining. Ensure that the pilot line system is leak-free, close all valves, and prepare for operation.
For more detailed information on installation and usage, refer to official guidelines or consult with a qualified technician.